Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Arch Oral Biol ; 164: 105978, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38718465

RESUMO

OBJECTIVE: To evaluate the effect of the association of potassium iodide to antimicrobial photodynamic therapy on human carious dentin produced with a microcosm biofilm model. METHODS: A microcosm biofilm model was used to generate a caries lesion on human dentin. Pooled human saliva diluted with glycerol was used as an inoculum on specimens immersed on McBain artificial saliva enriched with 1 % sucrose (24 h at 37 °C in 5 % CO2). After refreshing culture media for 7 days, the dentin specimens were divided in 5 groups (3 specimens per group, in triplicate; n = 9): C (NaCl 0.9 %), CX (2 % chlorhexidine), PKI (0.01 % methylene blue photosensitizer+50 mM KI), L (laser at 15 J, 180 s, 22.7 J/cm2), and PKIL (methylene blue + KI + Laser). After the treatments, dentin was collected, and a 10-fold serial dilution was performed. The number of total microorganisms, total lactobacilli, total streptococci, and Streptococcus mutans was analyzed by microbial counts (CFU/mL). After normality and homoscedasticity analysis, the Welch's ANOVA and Dunnett's tests were used for CFU. All tests used a 5 % significance level. RESULTS: CX and PKIL groups showed significant bacterial decontamination of dentin, compared to group C (p < 0.05) reaching reductions up to 3.8 log10 for CX for all microorganisms' groups and PKIL showed 0.93, 1.30, 1.45, and 1.22 log10 for total microorganisms, total lactobacilli, total streptococci, and S. mutans, respectively. CONCLUSION: aPDT mediated by the association of KI and methylene blue with red laser reduced the viability of microorganisms from carious dentin and could be a promising option for cavity decontamination.

2.
J Prosthodont ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38526464

RESUMO

PURPOSE: This study evaluated the effect of toothbrushing cycles on surface roughness (Ra), gloss (GU), and morphology of two zirconia finishing and polishing protocols. MATERIALS AND METHODS: An ultra-translucent zirconia disc was sectioned into rectangular plates (12 mm × 7 mm × 3 mm) and divided into two groups according to the polishing and finishing system used (diamond rubber abrasive/DRA or glazing/GLA). Bovine enamel (BEN) plates with the same dimensions were used as a Control. Specimens of zirconia and enamel were analyzed for Ra and GU (n = 11) and surface morphology by scanning electron microscopy (n = 3) before toothbrushing (baseline) and after 15,000 and 30,000 toothbrushing cycles. Ra and GU data were analyzed by ANOVA two-way and post-hoc Tukey's test (α = 0.05), while the surface morphology was analyzed qualitatively. RESULTS: The Ra decreased significantly after 30,000 toothbrushing cycles for DRA and GLA zirconia ceramics. DRA showed a higher GU at the baseline, after 15,000 and 30,000 toothbrushing cycles than GLA and BEN. Toothbrushing polished the zirconia, creating a smooth surface, while no changes were observed for BEN. CONCLUSIONS: The increase in toothbrushing cycles (30,000) changed the surface roughness of DRA and GLA zirconia ceramics. DRA zirconia presented the highest GU, which did not change with toothbrushing.

3.
Odovtos (En línea) ; 25(3): 82-98, Sep.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1529071

RESUMO

Abstract To evaluate the microtensile bond strength (µTBS) of two resin cements to 3D printed and milled CAD/CAM resins used for provisional fixed partial dentures. Blocks (5 x 5 x 5 mm) of three 3D-printed resins (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) were printed (Photon, Anycubic Technology Co.). A milled material (VitaCAD-Temp, VITA) was used as control. Half the specimens were sandblasted and the rest were untreated. Two blocks were bonded with the corresponding resin cement: PanaviaV5 (Kuraray Noritake) and RelyX Ultimate (3M Oral Care). After 24 hours, the bonded blocks were sectioned into 1 x 1 mm side sticks. Half the beams were tested for µTBS and the other half was thermocycled (5000 cycles, 30s dwell-time, 5s transfer time) before µTBS testing. A four way Generalized Linear Model (material*sandblasting*cement*aging) analysis was applied. VITA exhibited the lowest µTBS, regardless of the cement, sandblasting and thermocycling. Sandblasting significantly improved the µTBS of VIT, especially after aging, but did not improve the µTBS of 3D printed resins. Sandblasting was not beneficial for 3D printed resins, although is crucial for adhesive cementation of milled temporary resins. Airborne particle abrasion affects the integrity of 3D-printed resins, without producing a benefit on the microtensile bond strength of these materials. However, sandblasting is crucial to achieve a high bond strength on milled temporary resins.


Resumen Evaluar la resistencia adhesiva en microtracción (µTBS) de dos cementos resinosos a resinas CAD/CAM impresas y fresadas indicadas para restauraciones provisionales. Bloques (5 x 5 x 5mm) de tres resinas impresas (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) y una resina fresada (VitaCAD-Temp, VITA) fueron fabricados. La mitad de los especímenes fueron arenados y el resto no recibió tratamiento mecánico. Dos bloques con condiciones de tratamiento iguales fueron cementados con cemento resinoso (PanaviaV5 / Kuraray Noritake y RelyX Ultimate / 3M Oral Care). Después de 24 horas los bloques fueron seccionados en palitos de 1 mm² de área. En la mitad de los especímenes se midió la TBS inmediatamente y el resto fue termociclado (5000 ciclos, 30s remojo, 5s transferencia) antes de la prueba de TBS. Se aplica un análisis estadístico por Modelo Linear General con 4 factores (material*arenado*cemento*termociclado). La resina VITA presentó la menor µTBS, independientemente del cemento usado, el arenado y el termociclado. Sin embargo, el arenado aumentó la µTBS de VIT, especialmente después del termociclado. Por otro lado, el arenado no resultó en un aumento significativo de la µTBS de las resinas impresas. El arenado no fue beneficiosos para las resinas impresas, aunque es un paso crucial para la cementación adhesive de las resinas fresadas. El arenado afecta la integridad de las capas de las resinas impresas, sin generar un beneficio en la TBS.


Assuntos
Desenho Assistido por Computador/instrumentação , Cimentos de Resina/uso terapêutico , Cemento Dentário , Impressão Tridimensional/instrumentação
5.
J Esthet Restor Dent ; 35(2): 368-380, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35894446

RESUMO

OBJECTIVE: Evaluate the effect of thickness of high-translucency (HT) CAD/CAM materials on irradiance and beam profile from a blue light-emitting diode light-curing unit (LCU) and on the degree of conversion (DC) and maximum polymerization rate (Rpmax ) of a light-cured resin cement (LCC). MATERIAL AND METHODS: The direct output from the LCU, the light transmission and irradiance ratio (IR) through one conventional composite and nine HT CAD/CAM materials (0.5, 1.0, 1.5, or 2.0-mm thick; n = 5) were measured with a integrating sphere coupled to a spectrometer. The light beam was assessed with a beam profiler camera. The DC at 600 s and the Rpmax of one LCC was determined using a Fourier transform infrared spectrometer (n = 5). Data were analyzed by ANOVA followed by Tukey's tests, and Dunnett's test was also used for irradiance data (α = 0.05). RESULTS: A significant decrease in irradiance through all materials occurred as thickness increased. Thin CAD/CAM materials improved light homogeneity, which decreased with the increase in thickness. The DC of the LCC directly exposed to light was the same as when exposed to 45%, 25%, 15%, or 5% IRs. Rpmax decreased with the decrease in IR. CONCLUSIONS: Although the HT CAD/CAM materials reduced the irradiance from the LCU, minor effects were observed in the LCC's DC. CLINICAL SIGNIFICANCE: Despite the light attenuation of blue light through different CAD/CAM materials that were up to 2-mm thick, the degree of conversion of one brand of light-cured resin cement was clinically acceptable when the LCU was used for 30 s.


Assuntos
Lâmpadas de Polimerização Dentária , Cimentos de Resina , Polimerização , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Propriedades de Superfície , Resinas Compostas
6.
Int J Prosthodont ; 35(4): 460-468, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36125870

RESUMO

PURPOSE: To evaluate the effect of different luting techniques on the shear bond strength (SBS) of ultra-translucent multi-layered zirconia (UTML) after 24 hours and 1 year of water storage and to analyze the influence of primers on the wettability of the UTML MTU-6 surface. MATERIALS AND METHODS: Four commercial resin cements were evaluated: Variolink Esthetic LC (Ivoclar Vivadent); RelyX Ultimate (3M); Estecem II (Tokuyama); and Panavia V5 (Kuraray Noritake). Panavia V5 was tested with and without Panavia V5 Tooth Primer (Kuraray Noritake). The SBS immediately after cement/primer application and after aging, scanning electron microscopy of the surfaces, and the contact angle of the primers on the UTML surfaces were analyzed. RESULTS: At 24 hours, Panavia V5 with Tooth Primer exhibited the highest SBS. After 1 year, the SBS of Variolink Esthetic LC and Panavia V5 with Tooth Primer decreased, and RelyX Ultimate increased. There was no statistical difference between RelyX Ultimate and Panavia V5 with Tooth Primer at 1 year. For all groups, the rate of adhesive failures increased after 1 year. The highest contact angle was observed on the control (no primer) group, and the lowest contact angles were obtained when the YSZ surface was treated with Scotchbond Universal and the combination of Clearfil Ceramic Primer Plus and Tooth Primer. CONCLUSION: Clinicians should prefer 10-MDP-based cementation systems that can be properly polymerized to achieve a stable long-term bond strength to YSZ restorations. Also, the use of ceramic primers improves the capability of the cement to establish an intimate contact with the intaglio of the restoration.


Assuntos
Colagem Dentária , Cimentos de Resina , Colagem Dentária/métodos , Cimentos Dentários/química , Materiais Dentários , Cimentos de Resina/química , Água , Zircônio/química
7.
Photodiagnosis Photodyn Ther ; 40: 103123, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36115559

RESUMO

OBJECTIVE: To evaluate the efficacy of methylene blue (MB)-mediated antimicrobial photodynamic therapy (aPDT) doped with potassium iodide (KI) against oral microcosms biofilms cultured in dentin. METHODS: A saliva-glycerol stock formed from pooled human saliva was diluted in McBain artificial saliva with 1% sucrose (1:1), inoculated on bovine dentin blocks, and refreshed daily for 5 days. The biofilms were divided (n = 9/group) and treated with 0.9% NaCl (C), 0.2% chlorhexidine (CX), 0.01% MB + low-power laser 15 J, 88 mW, 180 s (PL), and 0.01% MB + 50 mM KI + laser (PKIL). Serial dilution was performed, and cellular viability (CFU/mL) was evaluated for total microorganisms, total lactobacilli, total streptococci, and S. mutans. Additional biofilms were cultured and treated (n = 4) for biomass determination (%BMR). The microscopic structure of the biofilms was observed by SEM. One-way ANOVA and Tukey tests were conducted (α=5%). RESULTS: Total microorganisms and total streptococci significantly reduced in biofilms treated with CX and PKIL when compared to C, but the CX, PKIL, and PL treatments did not differ from each other. Total lactobacilli and S. mutans showed a significant reduction in the CX, PL, and PKIL groups when compared to C, but with no difference between them. Biomass analysis showed a significantly reduction for CX and PKIL compared to C. SEM micrographs showed noticeable changes in bacterial membrane integrity for the PKIL and CX groups. CONCLUSION: The addition of KI to methylene blue-mediated aPDT in microcosm biofilms was effective in reducing oral microorganisms, but the effect was group dependent.


Assuntos
Anti-Infecciosos , Fotoquimioterapia , Bovinos , Animais , Humanos , Fotoquimioterapia/métodos , Azul de Metileno/farmacologia , Iodeto de Potássio , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico , Streptococcus mutans , Biofilmes , Anti-Infecciosos/uso terapêutico , Streptococcus , Clorexidina/farmacologia , Lasers
8.
J Esthet Restor Dent ; 34(7): 1051-1059, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35644927

RESUMO

OBJECTIVES: To evaluate the influence of dentin pretreatments on the push-out bond strength (POBS) of self-adhesive resin cements (SARCs) to radicular dentin. MATERIALS AND METHODS: Two experimental pretreatments (2.5% titanium tetrafluoride (TiF4 ) and 26% polyacrylic acid (PA)) and two SARCs: Maxcem Elite (MAX) and Calibra Universal (CAL) were used. For each cement, a control group was applied as indicated by the manufacturer. Sixty bovine incisors were restored (n = 10) and subjected to POBS evaluation. Failure mode, adhesive interface and surface morphology were analyzed by a Scanning Electron Microscopy (SEM) and resin infiltration was performed by confocal laser scanning microscopy (CLSM). Data for POBS and CLSM were analyzed by three-way ANOVA and Bonferroni post-hoc (α = 0.05). RESULTS: For MAX, both experimental pretreatments resulted in increased POBS in the cervical third, and for CAL, only the PA resulted in higher POBS in the cervical third. The most failures occurred between the dentin and the resin cement, except when TiF4 was applied. For PA, analysis of surface morphology showed open dentinal tubules, while TiF4 presented particle agglomerates. SEM and CLSM images confirmed presence of resin tags for both pretreatments. CONCLUSION: Pretreating radicular dentin with PA and TiF4 solutions improves the bond strength of SARCs.


Assuntos
Colagem Dentária , Cimentos de Resina , Animais , Bovinos , Colagem Dentária/métodos , Cimentos Dentários/química , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
9.
Dent Mater ; 38(8): 1271-1282, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35717230

RESUMO

OBJECTIVES: To evaluate the effect of post-curing times on the color change, flexural strength (FS), modulus (FM) and microhardness at different depths of four 3D printed resins. MATERIALS AND METHODS: A characterization of the light emitted by 3D-resin post-curing unit (Wash and Cure 2.0, Anycubic) was performed. The tested 3D printed resins were Cosmos Temp3D (COS), SmartPrint BioTemp (SM) Resilab3D Temp (RES) and Prizma3D BioProv (PRI) were evaluated under five different post-curing conditions (no post-curing or 5-, 10-, 15, and 20 min of post-curing). For color change analysis, 10 mm diameter x 1 mm thick discs (n = 7) were printed, and the luminosity, color and translucency were measured before post-curing as control, and repeatedly after 5 min cycles of post-curing until a total of 20 min was reached for ΔE00 [CIED2000 (1:1:1)] calculation. For FS and FM, 25 × 2×2 mm (n = 10, for each post-curing time) 3D printed bars were subjected to a 3-point being test. Knoop microhardness (KHN) was measured transversally on 5 × 5×5 mm blocks (n = 10, for each post-curing time). Color results were analyzed by one-way repeated measures ANOVA (factor: color change). FS and FM were analyzed by two-way ANOVA (factors: Material*Post-Curing Time). KHN was analyzed individually for each material by two-way ANOVA (factors: Depth*Post-Curing Time). RESULTS: The post-curing time significantly influenced the ΔE00, FS, FM and KHN of all the evaluated materials. COS and SMA presented ΔE00 values above the acceptability threshold after 5 and 10 min of post-curing, respectively. The FS of RES reached a plateau after 5 min of post-curing, and for PRI and SMA, the FS stabilized after 10 min of post-curing. The post-curing process improved the KHN of the tested materials, and longer exposure periods were associated to higher KHN values at all the evaluated depths. SIGNIFICANCE: A fine adjustment of the post-curing time is crucial to produce adequate mechanical properties in 3D-printed restorative resins, while minimizing the color alterations on the restorations. For the evaluated resins, 5-10 min of post-curing will result in adequate mechanical properties, without affecting the acceptability in the color of the material. However, the results are material-dependent, and evaluation of each specific resin is advised.


Assuntos
Resinas Compostas , Resistência à Flexão , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície
10.
Clin Oral Investig ; 26(5): 3899-3910, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35006294

RESUMO

OBJECTIVES: This study characterized a violet LED light (V-LED; bright max whitening) tooth whitening device and evaluated its efficacy on stained enamel compared to hydrogen peroxide (HP). MATERIALS AND METHODS: Characterization of the V-LED beam profile was performed using a laser beam-profiler. The irradiance was measured throughout an exposure cycle at 0- and 8-mm distances using an integrating sphere and a spectral radiometer. Bovine enamel/dentin blocks stained with black tea (BT), cigarette smoke (CS), or without staining (CONT) were subjected to V-LED or 40% HP (n = 10/group). Color parameters (ΔL, Δa, Δb, and ΔE00) were measured using a digital spectrophotometer. Light transmission was estimated through 1-mm-thick bovine enamel slices (n = 5). ΔL, Δb, ΔE00, and irradiance were analyzed by two-way ANOVAs and Tukey's tests, Δa by Kruskal-Wallis and Mann-Whitney tests, and light transmission by t-test (α = 5%). RESULTS: Heterogeneous beam distribution was observed for the emitting V-LED chips. After 20 sequential exposures, irradiance levels were reduced 25-50%, regardless of the distance from V-LED. Localized irradiance values were statistically different between beam locations and different distances from the target. V-LED produced lower ΔE00, ΔL, Δa, and Δb values than HP for CONT and BT, with no differences for CS. Light transmittance decreased approximately 98% through 1-mm thick enamel. CONCLUSIONS: V-LED irradiance was heterogeneous and decreased throughout the exposure cycles and was also greatly reduced with increasing tip distance. V-LED produced a significantly lower whitening effect on BT and control teeth. CLINICAL RELEVANCE: This study contributes to the knowledge of V-LED and its clinical use.


Assuntos
Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Cor , Esmalte Dentário , Peróxido de Hidrogênio , Luz , Chá , Clareadores Dentários/farmacologia
11.
Quintessence Int ; 53(3): 200-208, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34709774

RESUMO

OBJECTIVES: To compare the operative time and presence of air voids on Class II restorations fabricated by dental practitioners with 1 to 5 years of experience using incremental and bulk-filling techniques. METHOD AND MATERIALS: Four techniques were evaluated: incremental, bulk-filling, bulk-filling with heated composite, and snowplow technique. Standardized mandibular first molars with a MOD (mesial, occlusal, and distal) cavity were used. Voluntary operators made two restorations using each technique and the time required for each restoration was recorded. The restorations were scanned by micro-computed tomography to calculate the volume of the restoration occupied by air voids. The "operative time" and "volume of air voids" were analyzed individually by two-way ANOVA and Tukey HSD post hoc (α = .05) for the factors operator and insertion technique. A correlation between "operative time" and "volume of air voids" was evaluated using Pearson coefficient (α = .05). RESULTS: The incremental technique required significantly longer time, yet no differences were observed between the bulk-filling techniques. There were no significant differences between techniques regarding the volume of air voids. A significant, but weak, and inverse linear correlation (P = .0059; r = -.29; r2 = 8.41%) was found between the operative time and volume of air voids. CONCLUSION: There were no significant differences in the volume of air voids among the evaluated techniques, although bulk-filling techniques required a shorter operative time. Hence, implementing bulk-filling techniques by dental schools and restorative dental practitioners with different levels of expertise may reduce chair time and produce a volume of air voids similar to the incremental technique.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Preparo da Cavidade Dentária , Odontólogos , Humanos , Teste de Materiais , Duração da Cirurgia , Papel Profissional , Microtomografia por Raio-X
12.
J Esthet Restor Dent ; 34(2): 412-422, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34569699

RESUMO

OBJECTIVE: To evaluate the influence of shades of a multilayered zirconia on light transmission, resin cement degree of conversion, and shear bond strength of resin cement. MATERIALS AND METHODS: The light transmission through opaque (OPQ) and translucent (TNS) regions of Katana UTML zirconia (Kuraray Noritake Dental) were evaluated for using a spectroradiometer (n = 5). Degree of conversion of dual-cure resin cement (Panavia V5, Kuraray Noritake Dental) was measured after light-activation through OPQ or TNS regions and direct exposure. Composition of the zirconia was analyzed with energy dispersive x-ray spectroscopy (EDS). Shear bond strength (SBS) was evaluated on the OPQ and TNS regions after 24 h and 1 year from specimen preparation (n = 15). RESULTS: The OPQ region produced higher irradiance loss (95.1%) than TNS one (92.9%), and lower degree of conversion (52.4%) than TNS (71.2%) at 24 h post-light activation. EDS analysis did not show differences on the microstructure of the OPQ and TNS regions. There were no significant differences on the SBS between zirconia regions. For both zirconia regions, a significant reduction on the SBS occurred after aging, being 31.7% for OPQ and 38% for TNS. CONCLUSION: Both OPQ and TNS regions affected the light transmission through the multilayered zirconia. The OPQ region yielded the highest light attenuation and the lowest degree of conversion of resin cement. Different regions of the zirconia did not influence the SBS. Clinical significance Although opaque and translucent regions of the multilayered zirconia reduced the light transmission from LED curing unit and the degree of conversion of resin cement, the regions did not affect the resin cement adhesion.


Assuntos
Colagem Dentária , Cimentos de Resina , Cerâmica/química , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície , Zircônio/química
13.
Clin Oral Investig ; 26(3): 3141-3150, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34826031

RESUMO

OBJECTIVES: To evaluate the biaxial flexural strength (BFS), flexural modulus (BFM), and Knoop microhardness (KHN) of incremental and bulk-filled resin-based composites (RBCs) using extended curing exposure times. MATERIALS AND METHODS: Disc specimens (n = 8; 6-mm diameter) were fabricated using three stacked molds (0.5-mm thick for the top and bottom molds, and a 1-mm-thick center mold for the conventional and 3-mm thick for the bulk-fill RBCs). Conventional (Tetric EvoCeram/TCE and Filtek Z250/FIZ) and bulk-fill RBCs (Tetric EvoCeram Bulk Fill/TBF and Filtek One Bulk Fill Restorative/FOB) were evaluated. The stacked RBC-filled molds were light-cured for (1) the manufacturer-recommended exposure (MRE) duration; (2) 50%, and (3) 100% extension of the MRE. The BFS, BFM, and KHN of the top and bottom discs were measured. BFS and BFM were analyzed by three-way ANOVA (material*curing time*depth) and Tukey's post hoc (α = 0.05). KHN was analyzed by two-way ANOVA (curing time*depth) and Tukey's post hoc (α = 0.05). RESULTS: Extending the exposure duration did not change the BFS and BFM on the top of the RBCs, but the BFS and KHN increased at the bottom of bulk-fill RBCs. For the conventional RBCs, TCE showed the highest increase on BFS at the bottom, going from 53.6 MPa at T1 to 69.9 at T3. Among the bulk-fill RBCs, FOB presented the highest increase on the bottom BFS (T1: 101.0 ± 19.9 MPa, T3: 147.6 ± 12.9 MPa). For all RBCs and exposure times, BFS and KHN were lower at the bottom. Only FIZ and FOB reached a bottom-to-top hardness ratio of 80%, at T3 and T2. CONCLUSION: A significant increase on the BFS and KHN on the bottom of bulk-fill RBCs can be observed when the time of exposure to the curing light is double the MRE. However, extended exposure does not eliminate differences on the BFS and KHN between the shallow and deep regions of RBCs. TCE and TBF failed to reach an acceptable B/T hardness ratio at all evaluated exposure times. CLINICAL RELEVANCE: Mechanical properties of RBCs can be affected by insufficient polymerization, specially at deeper regions of the increment. Therefore, clinicians should consider applying twice the MRE to curing-light to polymerize the maximal increment thickness of bulk-fill RBCs.


Assuntos
Resinas Compostas , Materiais Dentários , Resistência à Flexão , Dureza , Teste de Materiais , Polimerização , Propriedades de Superfície
14.
Braz Oral Res ; 35: e120, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34878075

RESUMO

The purpose of this study was to describe the synthesis, characterization, and functionalization of b-NaYF4:30%Yb/0.5%Tm upconverting nanocrystals for use as nanofillers in a dental adhesive and microscopically evaluate the interface between the particles and a commercial adhesive. The upconverting nanoparticles were synthesized and purified by thermal decomposition, and their chemical composition determined by energy dispersive X-Ray spectroscopy. The crystalline structure was characterized using X-Ray diffraction and morphology and size were observed with scanning and transmission electron microscopy. Upconverting emission was evaluated by spectrophotometry irradiating the particles with a 975 nm diode laser. Particles were functionalized with polyacrylic acid and the success was confirmed by measurement of Zeta Potential and transmission electron microscopy. The results of X-ray diffraction found a pure hexagonal phase crystalline pattern. Scanning electron microscopy showed uniform dispersion of hexagonal-shaped particles of approximately 150 nm. Upconversion emission was observed in 344 nm, 361 nm, 450 nm, 474nm, 646 nm, 803 nm. Functionalization success was confirmed by formation of a stable aqueous colloid with a Zeta potential of -29.5mV and the absence of voids in the particle-adhesive interface on the transmission electron microscopy images. The reported synthesis and functionalization process produced upconverting nanoparticles emitting photons within the blue spectral region (450 nm and 474 nm).


Assuntos
Nanopartículas , Cimentos Dentários , Microscopia Eletrônica de Transmissão , Difração de Raios X
15.
J Esthet Restor Dent ; 33(4): 628-635, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33675162

RESUMO

BACKGROUND: Bulk-fill materials can facilitate the restorative procedure mainly for deep and wide posterior cavities. The purpose of this study was to evaluate flexural strength (biaxial flexural strength [BFS]) and microhardness (Knoop microhardness [KHN]) at different depths of bulk-fill materials. METHODS: Five bulk-fill materials were tested: two light-curable composite resins, one dual-cure composite, one bioactive restorative, and a high-viscosity glass ionomer. A conventional composite was used as control. BFS and KHN were tested at different depths. Data was analyzed by two- and one-way ANOVAs, respectively and Tukey's post-hoc (α=0.05). RESULTS: The high-viscosity glass ionomer material presented the lowest BFS at all depths. KHN for the two light-curable and the dual-cure bulk-fill resin composites was reduced following an increase in restoration depth, while the conventional composite, the bioactive material, and the high-viscosity glass ionomer were not affected. CONCLUSION: There are differences in the properties of the tested materials at 4 mm depth, showing that the studied properties of some materials vary according to the cavity depth, although the results are material dependent. CLINICAL SIGNIFICANCE: Mechanical properties of light-cured, bulk-fill materials may be affected by inadequate polymerization. Clinicians should consider complementary strategies to achieve adequate polymerization at high-increment depths.


Assuntos
Materiais Dentários , Resistência à Flexão , Resinas Compostas , Teste de Materiais , Polimerização
17.
Dent Mater ; 37(2): e47-e58, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33143939

RESUMO

OBJECTIVE: This study evaluated the effect of beam homogeneity on the microtensile bond strength (µTBS) of two adhesive resins to dentin. METHODS: One polywave light-emitting-diode (LED) LCU (Bluephase Style, Ivoclar Vivadent AG) was used with two different light guides: a regular tip (RT, 1010 mW/cm2 emittance) and a homogenizer tip (HT, 946 mW/cm2 emittance). The emission spectra and beam profiles were measured from both light guides. Extracted third molars were prepared for µTBS evaluation using two adhesive systems: Excite F (EXF) and Adhese Universal (ADU). Bond strength was calculated for each specimen (n = 10) at locations that correlated with the output of the two LED chips emitting blue (455 nm) and the one chip that emitted violet light (409 nm) after 24-hs and after one-year water-storage. The µTBS was analyzed using a four-way analysis of variance (factors: adhesive system, light guide, LED wavelength, and storage time) and post-hoc Tukey test (α = 0.05). RESULTS: EXF always delivered a higher µTBS than ADU (p < 0.0001), with the µTBS of ADU being about 20% lower than EXF. The light guide (p = 0.0259) and storage time (p = 0.0009) significantly influenced the µTBS. The LED wavelengths had no influence on the µTBS (p > 0.05). SIGNIFICANCE: Homogeneity of the emitted light beam was associated with higher 24-h µTBS to dentin, regardless of the adhesive tested. Also, differences in the composition of adhesives can affect their compatibility with restorative composites and their ability to maintain bonding over one year.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Resinas Compostas , Cimentos Dentários , Dentina , Teste de Materiais , Cimentos de Resina , Resistência à Tração
18.
Dent Mater ; 37(1): e1-e14, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33143940

RESUMO

OBJECTIVE: This study aimed to test the efficacy of photodynamic inactivation (PDI) mediated by curcumin with EDTA against Streptococcus mutans in planktonic suspension using blue LED light. METHODS: Antibacterial activity of curcumin and EDTA was evaluated by determination of their minimal inhibitory concentration (MIC) and minimal bactericidal concentration (MBC). The fractional inhibitory concentration index (FICI) was used to estimate the synergistic effect of various combination ratios of curcumin and EDTA against S. mutans. Cultures of S. mutans (18 h, 37 °C, 5% C02) were prepared to test the effect of curcumin-mediated PDI (50 µM and 500 µM) with or without 0.4% EDTA and 40 s of light-activation with blue light. EDTA and each concentration of curcumin were also tested individually. Chlorhexidine (0.2%), was used as positive control. Planktonic suspensions were also analyzed by viable colony counts (VCC), confocal laser scanning microscopy (CLSM), transmission electron microscopy (TEM), and polymerase chain reaction (PCR). RESULTS: The MIC values of curcumin and EDTA were 5 mM and 0.125% respectively. FICI showed a synergistic interaction between curcumin and EDTA. All the combinations with curcumin and blue LED light resulted in a complete inactivation of the S. mutans and CLSM confirms these results, TEM showed morphological changes produced by the PDI. No damage on DNA structure was detected by PCR. SIGNIFICANCE: Curcumin-mediated PDI with EDTA using a blue light, shows a strong inhibitory effect against S. mutans in planktonic culture. Because of the unspecific target mechanism, it could be a promising technique for disinfection of dental tissues.


Assuntos
Curcumina , Fotoquimioterapia , Biofilmes , Curcumina/farmacologia , Ácido Edético/farmacologia , Fármacos Fotossensibilizantes/farmacologia , Streptococcus mutans
19.
Braz. oral res. (Online) ; 35: e120, 2021. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1350372

RESUMO

Abstract: The purpose of this study was to describe the synthesis, characterization, and functionalization of b-NaYF4:30%Yb/0.5%Tm upconverting nanocrystals for use as nanofillers in a dental adhesive and microscopically evaluate the interface between the particles and a commercial adhesive. The upconverting nanoparticles were synthesized and purified by thermal decomposition, and their chemical composition determined by energy dispersive X-Ray spectroscopy. The crystalline structure was characterized using X-Ray diffraction and morphology and size were observed with scanning and transmission electron microscopy. Upconverting emission was evaluated by spectrophotometry irradiating the particles with a 975 nm diode laser. Particles were functionalized with polyacrylic acid and the success was confirmed by measurement of Zeta Potential and transmission electron microscopy. The results of X-ray diffraction found a pure hexagonal phase crystalline pattern. Scanning electron microscopy showed uniform dispersion of hexagonal-shaped particles of approximately 150 nm. Upconversion emission was observed in 344 nm, 361 nm, 450 nm, 474nm, 646 nm, 803 nm. Functionalization success was confirmed by formation of a stable aqueous colloid with a Zeta potential of −29.5mV and the absence of voids in the particle-adhesive interface on the transmission electron microscopy images. The reported synthesis and functionalization process produced upconverting nanoparticles emitting photons within the blue spectral region (450 nm and 474 nm).

20.
Eur J Oral Sci ; 128(4): 336-344, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32502304

RESUMO

This study evaluated the effect of extending the duration of exposure to curing light on the depth of cure of two conventional (RBC1-conventional and RBC2-conventional) and two bulk-fill (RBC1-bulk and RBC2-bulk) resin composites. Polywave and single-peak photocuring units were used. Cylinder-shaped specimens were exposed to curing light either for the time period recommended by the manufacturer or twice the length of that time, and depth of cure was estimated using manual scraping (similar to the ISO-4049 standard) and solvent immersion techniques. Depth of cure was analyzed, using two-way ANOVA, for the factors measurement method and exposure time. For RBC1-conventional and RBC1-bulk, the solvent immersion technique estimated a greater depth of cure than did manual scraping; for RBC1-conventional, both techniques and both light-exposure time periods resulted in a depth of cure of >2 mm; and for RBC1-bulk, only the solvent method after photocuring for twice the manufacturer's recommended time resulted in a depth of cure of 5 mm. For RBC2-conventional and RBC2-bulk, neither technique nor exposure time resulted in estimated depths of cure that matched those indicated by the manufacturer. The results suggest that extending the duration of photopolymerization increases depth of cure. Also, calculation of depth of cure can vary according to the measurement technique used.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Dureza , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Polimerização , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA